Dear engelmaier,

      Another question to distrub you:

      As you recommand, IPC-D-279 Appendix A  Table A-1 say thermal cycle use -40~85 dwell time is 12h  to test a solder joint reliability of telecom product, but in Mil-std-883, it use a dwell of  >10mins to cycle, which to choose when experiment&FEM simulate  ? what different with them? and as use IPC-D-279 recommanded, the test will be too long(a day/cycle), how we can do?

    

Best Regard,

Liu changkang 

Huawei Technology Co., Ltd.

      

  