Hi All,


Got an issue here raised by one of our IPC-A-600F users.  The attached .pdf contains a photograph that shows the board edge of a sample which the user believes does not pass the criteria established in section 2.1.1.1., Nonmetallic Burrs.  It would appear as though the router had some problems on the edges and fiberglass fibers are now falling off the edges.

Does this provide sufficient information in order to obtain a consensus from this group on the pass/fail issue?


Best Regards,




John Perry