Sounds as if it may be that someone has no face mask on when coughing
(serious). I had this happen once in a former life. Took a week to track
it down.

Brian

Franklin D Asbell wrote:
>
> Happy Holidays people... hope things are going well for everyone...
>
> I have some questions regarding lifted resist problems, our Process
> Engineer is quite convinced we have a resist lifting problem due to the
> double-treat and drum-treat laminates we purchase.
>
> What we have been seeing are very isolated areas of resist lifting after
> developing, areas down space lengths around 50 75 mils long. I have not
> seen any total separation from the copper but I have seen lifted edges,
> again, in very isolated areas, typically not more than 1 instance per
> panel, and then only on appr 10% - 15% of the total panel lot.
>
> We identify this at AOI prior to etch.
>
> I don't have the camera here or i'd snap a few pics for you, even then I
> don't think it'd turn out well as they are very small areas.
>
> Anyway, I find it hard to believe contaminates on foil, responsible for
> lifting resist can occur in such minute areas and so infrequent
> throughout the lot.
>
> Any assistance would be appreciated, thanks
>
> Franklin D Asbell
> Network Circuits
> Irving, Texas ~tucking the Cowboys banner down under the desk, out of
> sight, grin~
>
> ---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> ---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2