Allen,
I think you may be referring to the 'PerfecTest' coupon.  The coupon is 
used in conjunction with a Perfectest probe for verifying inner layer 
registration.  For more info, contact American testing Corporation at 
800-635-5384.  Hope this helps.

Rob Eckwall
Proto Engineering Corporation


At 04:11 PM 11/17/00 +0800, you wrote:
>Dear techneters,
>
>Do you have any idea about the "Perfect Coupon"?
>I heard that it was applied on the  high layer count products to verify 
>layer registration (both x & y direction), via plating resistance.etc.
>Could someone describe how to design this coupon?
>
>Thanks a lot!
>
>Allen Hu(­J§»¶©)Q80_5380
>Q&R Engineering Section
>Quality Assurance Department
>Tel:886-3-3231111 ext:5363
>Fax886-3-3235874

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2