Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Tue, 14 Nov 2000 09:58:22 +1100 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Just another possibility, is that the boards were warped after bare board
fabrication and then flattened in a post-fab process to come within spec.
Then, reflow relaxes the stresses in the boards and they return to their
original warped state.
Phil Dutton C.I.D.
Senior CAD Technician
IPC Certified Interconnect Designer
Tenix Defence Systems Pty Ltd
Systems Division - Adelaide
Second Avenue, Technology Park,
Mawson Lakes. SOUTH AUSTRALIA 5095
================================
Phone (08) 8300 4400 (reception)
Fax (08) 8349 7420
email [log in to unmask]
Internet Page http//www.tenix.com
================================
-----Original Message-----
From: Malewicz Wesley [mailto:[log in to unmask]]
Sent: Tuesday, 14 November 2000 1:38
To: [log in to unmask]
Subject: [TN] Warp/Bow after reflow
Importance: High
Hi,
What are some of the contributors that would cause a .040 thick PCB in a 12
up panel, routed and scored, with components mounted on both sides, to
warp/bow after reflow.
Thanking you in advance for your suggestions.
Wes Malewicz
Printed Circuit Development Supervisor
Siemens Medical EM-PCS
email: [log in to unmask]
-
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|