We assemble PCB for space applications so it is clearly a class 3 board.
And we are allowed to rework one time each solder joint. So that means that
every joint can be  touched up one time.
After, we have to change the component.

So, I think you customer has missed something !

Vincent Bada
Process Engineer
Alcatel ETCA
Belgium





mike connolly <[log in to unmask]> le 25/09/2000 14:28:10

Veuillez répondre à "TechNet E-Mail Forum." <[log in to unmask]>; Veuillez répondre
      à mike connolly <[log in to unmask]>

Pour :    [log in to unmask]
cc :   (ccc : Vincent BADA/ETCA/ALCATEL-SPACE)
Objet :   [TN] IPC-R-7221





Fellow Technets, A question was posed to me by a customer claiming that IPC-R-7221 stated that a maximum of 1 rework per board for class 3 was acceptable. Specifically they stated that this means only 1 solder joint per board could be touched up. I have been searching high and low for IPC-R-7221 but to no avail have yet to find the existence this publication. My questions are: 1. Does IPC-R-7221 exist? 2. If so, can anyone support or refute the claims of only being able to touch up 1 solder joint on a class 3 assembly? Any help or input would be appreciated. Best regards, Mike __________________________________________________ Do You Yahoo!? Send instant messages & get email alerts with Yahoo! Messenger. http://im.yahoo.com/ ############################################################## TechNet Mail List provided as a free service by IPC using LISTSERV 1.8d ############################################################## To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body: To subscribe: SUBSCRIBE TECHNET <your full name> To unsubscribe: SIGNOFF TECHNET ############################################################## Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information. If you need assistance - contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315 ##############################################################