Anil, are you acquainted with techniques for assessing measurement quality like those in the QS-9000 Measurement Systems Analysis handbook?  From what you're saying, this information would be useful.  Also, I recommend Evaluating the Measurement Process by Don Wheeler, ISBN 0-945320-06-X.  For some time I've been saying that the basis of success in engineering is understanding the variability in your measurement process.  Lou Hart
Quality Assurance
Compunetix

----------
From:   Anil Kher[SMTP:[log in to unmask]]
Sent:   Friday, August 11, 2000 5:29 AM
To:     [log in to unmask]
Subject:        [TN] About potassium gold cyanide KAu(CN)2 - analysis.

<<File: ATT00002.htm>>
Dear all and Rudy especially,

I have a problem in analysing Gold content reliably in a citrate bath - using an AAS and a Gold lamp at 242.8 nm - the reading variance is 10%. The basic absorbance is at the absurd level of 5 ppm and the max  absorbance is at 6 ppm. i.e basic is say 0.250 and max at 6ppm is .490. (The AAS manufacturer is not attuned to base rdg should be less or equal to lower end resolution concept) Finally the variance in reading is like 0.5 ppm. Plotting a curve after suppression etc with all these variations I am as close to +/- 15%. Gravimetric is too long. Does anyone know better - say 2- 3% accuracy??
 
Further we use a KAuCn2 as std. the corresponding readings for the complex bath - at equivalent Gold - say 1 ppm / 3 ppm etc. are lesser at 90% absorbance - ( even with 5% HCL) 

Grateful
Anil Kher

  
micro interconnexion pvt. ltd.
D3-12 A , Corlim Industrial Estate, Corlim , Ilhas , Goa , India - 403110 
Tel : 00-91-832-284209 / 284337. Fax : 284209. E - Mail : [log in to unmask]
LEADERS IN GOLD PLATED PCBs.

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################

ATOM RSS1 RSS2