We run copper plating tests monthly and send these to an independent lab
for testing. The requirements are Tensile Strength 36,000 psi minimum
and Elongation 6% minimum. My question to the experts is-- what if our
readings were high, i.e. 43,000 psi and 20% elongation?
TIA,
Rick Howieson