Jarmo

Now there's a good question. At any given point on the time scale, provided you express
the value in arithmetic ohms and not in log10 ohms, I would say the arithmetic mean and
variance or SD. However, I believe that this is relatively meaningless unless you wish
to plot the whole time x R curve with SD limits, because the curve is probably noisy.
If you wish a mean end-value, I think you should average all the readings over the last
several hours. Better still, use exponential curve-fitting techniques on all the plots
over the total time and average plus SD each of the parameters and plot a new curve
from this: this would be the best statistical method, requiring a little
number-crunching using a good mathematical software (don't try it in a spreadsheet
application: you'll come to a very sticky end, it's a promise!).

Brian

Kiiski Jarmo wrote:

> To estimate the average of SIR-test results should arithmetic or geometric
> mean used and how standard deviation should calculated?
>
> B.R.
> Jarmo Kiiski
>
> ##############################################################
> TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
> ##############################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
> the body:
> To subscribe:   SUBSCRIBE TECHNET <your full name>
> To unsubscribe:   SIGNOFF TECHNET
> ##############################################################
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
> information.
> If you need assistance - contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> ##############################################################

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################

ATOM RSS1 RSS2