Looking for suggestions on how to tweak soldermask process and/or immersion tin
process to decrease ionic contamination levels after immersion tin.
Soldermasks
Hysol/Dexter SR-1000 - thermal cure
Enthone DSR-3241(I) - thermal cure w/ no UV bump
Tin
MSA based chemistry, 155F/15min
Hot city water rinse 100F/2min
2 x Cold DI rinse 2 min
conveyorized double cascade DI rinse & dry
Ionic contamination levels measured w/ omegameter and Alpha ionograph
after soldermask & before immersion tin = < 5 mg NaCl eq/in2
after immersion tin = > 30 mg NaCl eq/in2
##############################################################