In a message dated 06/29/2000 8:09:21 PM Central Daylight Time,
[log in to unmask] writes:

> Hi Ruby,
>  There are no specifications that address this specific issue; there are
some
>  statements in some IPC specs (cannot give them to you, because I am on the
>  road) talking about fill percentages, but that has nothing to do with PTH/
> PTV
>  barrel wall failures. Also, when I am called in by clients with problems,
it
>  is understandable that they do not want to publicize those.
>  Werner Engelmaier

Hi Werner, Ruby, and all,

This subject is what started my ranting from previous posts. If you go back
to what I was asking about if fab vendors could fill vias during fabrication,
I was just trying to learn if it was possible. Because we're going to be
getting boards that will have all the vias relieved in the soldermask layer
because of the desire for expanded ICT test coverage, but was told that it
would be too much work to go to each and every assembly (there are a number
of them) and relieve only the vias needed for the expanded ICT...so the easy
solution for them would be to do a global thing to relieve all vias of the
soldermask...no matter if the assembly still uses LCCC's and all the data out
there is about partial via fill...(not to mention the cleaning issues)

I was just ranting if this was the smart thing to do...and the fact that no
matter how much I try to relate what I've learned from this distinguished
list that some will ignore the facts...you guys are my buddies.

Some chose to ignore the truth...the customer is always right I guess.

-Steve Gregory-

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################

ATOM RSS1 RSS2