The gold thickness requirement for sliding contacts (edge connectors) for UK
telecomms used to be 5 microns (0.0002") gold on copper, based on the fact
that this would withstand thousands of insertions. This was reduced to 2.5
microns gold, direct on copper or with a nickel underplate.

Can't believe these standards are still used since nowadays there is no need
for so many insertions.

Geoff Layhe
www.lamar-uk.co.uk

> ----------
> From:         <Rudy Sedlak>[SMTP:[log in to unmask]]
> Reply To:     TechNet E-Mail Forum.;[log in to unmask]
> Sent:         14 June 2000 04:22
> To:   [log in to unmask]
> Subject:      Re: [TN] Gold over Copper?!? (II)
>
> We do not make PCB's, we make the chemicals that make the PCB's.
>
> I have been to the UK many times on business, and found this out.
> Typically,
> the gold was electroplated, and was at least 40, and I seem to recall 60
> millionths of an inch thick, (1-1.5 microns), and it may have been more,
> and
> yes, it did alloy with the Copper, but it took a long long time to alloy
> with
> that much Gold, and it soldered very well.
>
> So, IF you must put Gold on to Copper, make sure it is REAL thick.
>
> Rudy Sedlak
> RD Chemical Company
>
> ##############################################################
> TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
> ##############################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
> following text in
> the body:
> To subscribe:   SUBSCRIBE TECHNET <your full name>
> To unsubscribe:   SIGNOFF TECHNET
> ##############################################################
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
> additional
> information.
> If you need assistance - contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> ##############################################################
>

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################

ATOM RSS1 RSS2