Gary:  While not straight to the point, I recall a thread talking about ... "1825 and larger
should not be used on FR4 due to the CTE missmatch on a ceramic part that large, however the
1812's should be OK. Yes we have also run a 2225 caps on FR4, but as a general DFM rule we
have tried to stick to below 1825 for use on FR4."

Dave Fish


Gary Camac wrote:

> Good afternoon,
>
> I have been asked by our PWB layout dept. if they can put a 2512 on the wave soldered side
> of an assembly.  I checked the archives to no avail - so here I am.  We have successfully
> populated this size part on both sides of double-side reflow PWAs.  I am a little dubious
> about wave soldering them.  Am I right or can this be done?
>
> Thanks in advance
>
> Gary Camac

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################

ATOM RSS1 RSS2