Thank you for your responses to my "External Blind Via annular ring" query.
I should have explained a little more on why I asked.

The board has already been designed well below reduced producibility.
According to IPC-2221, the external annular ring should have been .024" dia.
at a minimum.  If the hole to pad is tangent on the finished board, I do not
believe it would be detrimental to final assembly.

The board design is more like a Micro Via, but it is a drilled via hole that
will be filled.  The external pads are .018" dia. The Internal pads are
.021"dia.  The drilled blind via hole is .010" dia. The blind via subs are
approximately .035"-.040" thick.  The minimum conductor widths are .005" and
the minimum spacings are .004".  The board has 14 layers and an integral
copper core (.035"-.040" thick). The finished overall thickness of the board
is .125".  The finished outline dimensions are approximately 6" x 9".  The
BGAs (3 of them) will be mounted directly to the plated over surface of the
filled Blind Via.

I have not seen this type of design being discussed on the Tech Net, nor
covered in the specs.  Bits and pieces that are similar, but not all in one
package.

Any comments would be appreciated.

THANK YOU,
Dawn Patterson

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################

ATOM RSS1 RSS2