In a message dated 05/31/2000 10:39:40 AM US Eastern Standard Time,
[log in to unmask] writes:

> You can measure the ionic contamaination levels.  An Omegameter works well.

As a process control tool yes.  As a measure of cleanliness for accept-reject
- no way.  Inquirin' minds should read EMPF report RR0013, "An In Depth Look
At Ionic Cleanliness Testing", done in conjunction with the IPC Ionic
Conductivity Task Group about 5 years ago.  It should be available from
www.empf.org.

Doug Pauls

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################