Mark
First let me make sure that when you refer to 8 thou you mean 0.008"?
That's what I'm basing my comments on.
8 mil trace/space on 2 oz copper should not be a problem for most board
manufacturers who regularly process 2 oz copper. Our capability for 2 oz
layers at Merix extends down to 6 mil trace/space. I would consider 8/8 a
comfortable design.
I don't see a reason why the inner layers couldn't be plated up to 2 oz
copper thickness, but I also don't see a reason to do it. I suppose 2 oz
clad materials might not be as common as 1 oz and therefore a little harder
to obtain, especially for very short lead-time parts. With a little
planning you should be able to get your boards built "properly" with 2 oz
foil.
Mike McMaster
RF Product Engineer
Merix Corporation
503-992-4263
----------
From: Mark Holmes [SMTP:[log in to unmask]]
Sent: Tuesday, April 11, 2000 3:23 AM
To: [log in to unmask]
Subject: [TN] 8 Thou tracks in 2oz Copper
Hello all,
I have a question for all you board manufacturers (and PCB
designers) out
there. I have been working on an unusual 4-layer board which has 2oz
copper
on all layers. The majority for the tracking is on the inner layers,
and the
outer layers are effectively solid planes of copper. Many of the
tracks on
the inner layers have to carry a lot of current, but there is also
some
control circuitry which requires a clearance of 6.5mm from the high
power
area. Here lies my problem. Due to the space limitations and
clearance
required, I have tracked in a connector using 8th tracks which
travel almost
the length of the board (around 110mm) along one edge. These 3
tracks are on
their own, 6.5 mm from the rest of the tracking, adjacent to each
other with
8th gaps.
My question is - is this achievable? how much of a problem would
this cause
the manufacture? The inner layers MUST be 2oz copper.
My second question is - If 2oz of copper was specified for all
layers, is it
acceptable to plate up the inner layers from 1oz copper foil?
A manufacture told me they had done this (although in fact they had
not!)
but I have never heard of this practice for inner layers before.
This is a hot issue for me a the moment and I would appreciate any
advice or
comments.
Best Regards,
Mark Holmes
[log in to unmask]
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV
1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with
following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################
|
|
|