I'm struggling a bit with IPC-TM-650 Method 2.5.5.7. The test requires
you to take a measured mean voltage value but does not indicate how many
measurements should be taken. Also, is IPC going to change/revise this
test method to reflect newer test technology/methodology? I'm waiting on
a recent report published by INTEL that addresses a different technique
than what is in TM-650 and would be happy to pass this on to those
interested.
Any info appreciated.
Rick Howieson