We have always taken the interpretation that the narrowest feature can have isolated reductions down to 80% of the minimum specified on the drawing. All other widths we allow 30% reduction of the existing width. We are comfortable with this since a overall 20% of the master is allowed and additional 20% isolated reductions are acceptable. This requirement was developed from IPC-FC-250 table 8 which allows 35% reduction from the master width.
##############################################################