Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Tue, 29 Feb 2000 12:54:12 +0200 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Adeodato
It is about a hundred years since I did this, so what I say is certainly
out of date! Our preferred method was to clean the board with a good hot
(55°C) agitated DI water wash with 10% IPA, followed by a single DI
rinse at 85°C, followed by a 30°C dilute sodium persulfate (not
ammonium) etch to remove c. 2 um of copper followed by 3 DI rinses.
Oxide-free drying was done by successive pure IPA (to remove the gross
water) and toluene displacement, followed by placing in a walk-in oven
with filtered air at 30°C for 5 hours minimum.. This produced a residual
ionic contamination of < 0,3 ug/cm2 eq. NaCl, where the then MIL-P-55110
suggested a max of about 1,3-1,5 ug/cm2 eq. NaCl depending on your
interpretation. Solderability was excellent. We did this with both dry
film and liquid screened masks. Do NOT use abrasives or brushing of any
sort: you smear epoxy onto the copper and implant abrasives into the
copper, causing a certain dewetting (see my book for full details).
Brian
Adeodato Vigano wrote:
> TechNet,I would like to hear the Forum's opinions about pre-cleaning
> before soldermask (both Dry Film and LPI), in particular about the
> methods based on chemical rather than mechanical action.We are
> evaluating an "oxide replacement" chemistry versus different microetch
> chem-clean systems. The microetch would be our preference because
> running thick panels through our oxide replacement equipment may
> result in damage to the line, of course we are getting good results
> from the oxide replacement chemistry but we are not getting consistent
> results from the chem-cleaning process.Also I would like to know what
> other PCB manufacturers are doing when they are not using mechanical
> scrubbing methods.Any suggestions regarding chemistry and/or process
> parameters would be greatly appreciated.Thanks in advanceadeodato
> viganocompunetics, inc. - pcb divisionphone: 412.858.6115fax:
> 412.858.8060email: [log in to unmask]
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################
|
|
|