TECHNET Archives

January 2000

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
edward edward szpruch <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Mon, 24 Jan 2000 07:25:29 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (35 lines)
Hi,
We are using portable instruments made by Caviderm and by CMI.Both of them
are limited by holes diameter ( 0.76 mm for Caviderm , 0.9 mm for CMI ) ,
board thickness ( max 2.4 , min. 1.0 mm) .The measurement is an average
without indication of minimum.
Most our boards are with 0.25 - 0.30 mm drilled vias , thickness from 0.1 to
6 mm , point of interest is mainly minimum thickness of plated copper since
average in high aspect ratio is rather meaningless.
Of course it is desirable to have possibility to take such measure on plated
boards before etching.
What kind of instruments are available and what is practical field
exerience?
Regards


Edward Szpruch
Eltek , Manager of Process Engineering
P.O.Box 159 ; 49101 Petah Tikva Israel
Tel  ++972 3 9395050 , Fax  ++972 3 9309581
e-mail   [log in to unmask]

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################