Dear James

目前碰到一個客戶要求測試方式遵循J-STD-003B要求.但是測試時用的助焊劑
又和003B要求不同.所以出現了測試差異.如用003B的二號助焊劑做焊錫實驗是合格的
但是改用004 中的ROL1卻是不合格.正確使用方式是否為003B才正確.

BR
Leo

-----Original Message-----
From: TGAsia [mailto:[log in to unmask]] On Behalf Of James Liu
Sent: Thursday, June 03, 2010 5:07 PM
To: [log in to unmask]
Subject: [TGAsia] 答复: 問題請教

003B中的2号助焊剂是专门用来测试的专用助焊剂,下面的表4-1中有详细的成份说明。而004中的助焊剂是生产用助焊剂,因此004中没有此类助焊剂。


Best Regards,

James Liu 刘春光
Director, Industry Programs 工业项目总监
IPC China
上海市长宁区延安西路1088号2303室
Suite 2303,#1088 West Yan'an Rd., Changning, Shanghai 200052 PRC
Tel:   +86 21 5497 3435
Fax:  +86 21 5497 3437
MP:   +86 136 0133 3491
[log in to unmask]
www.ipc.org.cn

-----邮件原件-----
发件人: 黃志宏經理 Leo [mailto:[log in to unmask]] 
发送时间: 2010年6月3日 16:30
收件人: Listserv TGAsia; James Liu
主题: 問題請教

Dear James

1在 J-STD-003B 3.2.2 中規定無鉛測試用的助焊劑應當為 2 號標準松香助焊劑
 想請教表內的1號及2號助焊劑.是屬於 J-STD-004B 表3-2 中的哪一個類型?

2.若2號助焊劑是屬於ROM1 . 客戶要求使用ROL1類型助焊劑來做測試是否洽當.

BR
Leo
-----Original Message-----
From: 黃志宏經理 Leo 
Sent: Friday, May 28, 2010 9:12 AM
To: 'Asia Committe Task Group Forum'; 'James Liu'
Subject: RE: [TGAsia] 答复: 放大镜的照度要求

Dear James

但是參照 IPC-A-610D 1.8 並未清楚寫出照度要求
是否在其他規格中有寫到呢?

BR
Leo

-----Original Message-----
From: TGAsia [mailto:[log in to unmask]] On Behalf Of James Liu
Sent: Thursday, May 27, 2010 10:00 PM
To: [log in to unmask]
Subject: [TGAsia] 答复: 放大镜的照度要求

1000流明的照度。


Best Regards,

James Liu 刘春光
Director, Industry Programs 工业项目总监
IPC China
上海市长宁区延安西路1088号2303室
Suite 2303,#1088 West Yan'an Rd., Changning, Shanghai 200052 PRC
Tel:   +86 21 5497 3435
Fax:  +86 21 5497 3437
MP:   +86 136 0133 3491
[log in to unmask]<mailto:[log in to unmask]>
www.ipc.org.cn<http://www.ipc.org.cn>

发件人: TGAsia [mailto:[log in to unmask]] 代表 Frank Lan
发送时间: 2010年5月27日 14:15
收件人: Listserv TGAsia
主题: [TGAsia] 放大镜的照度要求

Hi all,

IPC610中规定了放大镜的使用,并要求照度能满足要求。请问照度要求的具体数值应该是多少?

Best regards,
Frank Lan
Ext. 6889

[cid:[log in to unmask]]




=======================================================================
This e-mail is intended for the person it is addressed to only. The
information contained in it may be confidential and/or protected by
law. If you are not the intended recipient of this message, you must
not make any use of this information, or copy or show it to any
person. Please contact us immediately to tell us that you have
received this e-mail, and return the original to us. Any use,
forwarding, printing or copying of this message is strictly prohibited.
No part of this message can be considered a request for goods or
services.
=======================================================================

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2