TECHNET Archives

December 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Brad Kendall <[log in to unmask]>
Reply To:
TechNet Mail Forum.
Date:
Mon, 15 Dec 1997 12:40:21 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (38 lines)
John,
     I have set up 2 such solder paste measurement systems.  One at my
previous employer and now one at my new employer.  In both cases I choose
the Alpha Hi-check system over the Cyberoptics unit.  But, regardless of
the equipment you should try to measure to the pad surface.  If you are
undercutting you stencils at all (most do) you will have some exposed pad
to measure to.  This will give you your truest number as far as the actual
thickness goes.  In experiments where I did not have any stencil reduction
I would measure pad height from substrate, then print, then measure
substrate to paste and find the difference.  But in production we use the
edge of the pad from the stencil reduction to the paste.  We measure 5
locations on a board: all 4 corners and the center- however if BGA or fine
pitch is used those are measured.  We measure the 3rd piece of each run
(not the first of second because of paste kneading), and the again at the
mid point of the run.

     If you are using organic coating instead of HASL and are not worried
about the true paste thickness you could measure from the substrate to the
paste.  The copper should be consistent enough to give you the consistency
you need.  This will allow you to track the consistency of the paste
printing process, just not necessarily the true paste thickness.  My
recommendation is to use the actual pad surface if at all possible.

Good luck,
Brad Kendall

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
##############################################################


ATOM RSS1 RSS2