TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Date:
Mon, 29 Jul 1996 17:12:50 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (16 lines)
Besides turbulent flow at the nozzle, you may be getting viscosity increases
due to a fast evaporating solvent or your boards may be too warm when being
sprayed.  This type of problem is seldom due to a contaminant on the surface,
but don't rule it out. There could be some sort of additional outgassing when
the surface of the mask softens due to the solvent in the conformal coating.
 More information is needed.

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************



ATOM RSS1 RSS2