Thank you Susan for "plugging" our work. I was just about to say the same
thing.There has been a lot of work on trying to classify the method whether
it be plugging,filling and/or capping and the various things that you be
worried about.
Dewey

> -----Original Message-----
> From: Susan Mansilla [SMTP:[log in to unmask]]
> Sent: Monday, March 22, 2004 7:58 AM
> To:   [log in to unmask]
> Subject:      Re: [TN] Plugged Via bubble
>
> There is an IPC committee D-33d Via Protection that has some
> information/guidelines  ina type of user's guide for via fill along with
> via protection.  You
> can pick up the latest strawman we are working on at their committee page
> on
> the IPC website.
>
> Later this week there is a teconf to establish what attributes should be
> included in
>  industry user's guide as well as to initiate a round robin testing plan
> for
> developing acceptance criteria.   Currently there is a listing of various
> different acceptance criteria different companies use.
>
> Last week when we were talking about solder voids in vias, Werner
> cautioned
> that these could present a real realiability issue, but voids in fill
> materials
> and conductive fill materials did not pose the same reliability problems.
>
> Please let John Perry know if you would like to join D-33d in its' efforts
>
> and stay tuned to learn how you can help and benefit from the effort.
>
> Susan Mansilla
> Robisan Lab
>
>
>
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2