From: Brian Ellis <[log in to unmask]>



Date: Fri, 11 Apr 2008 18:49:53 

To:[log in to unmask]

Subject: Re: [TN] Possible flux contamination issue





24 years ago (yes 24!), I gave a paper at InterNepcon, in Brighton, UK, 

entitled "Contamination on Components  and Small Assemblies". I no 

longer have a copy, but I'm fairly sure I evoked the need to have all 

the components supplied clean to avoid just this kind of problem.



Brian



Steve Kelly wrote:

> Good Morning,

> 

> We are assembling a BGA connector onto a flex circuit. The BGA has leaded

> balls and the BGA manufacturer uses a no-clean process to attach the balls

> to the connector and does not clean afterwards. 

> 

> When we assemble the BGA connector to the flex we use water soluble paste

> and then we clean. After damp heat cycling we have seen some shorts. When we

> take off the connector we see flux residues on the underside of the

> connector but not on the flex.  So my question is - what are the concerns

> about mixing no-clean and water soluble? Is the failure likely due to

> inadequate cleaning or is there something else I should be concerned about.

> I realize this is probably not the way it should be done but some days you

> just do what the customer wants - good or bad. Thanks in advance. Steve

> Kelly

> 

>  

> 

> Steve Kelly

> 

> (416) 750-8433 (work)

> 

> (416) 750-0016 (fax)

> 

> (416) 577-8433 (cell)

> 

>  

> 

> 

> ---------------------------------------------------

> Technet Mail List provided as a service by IPC using LISTSERV 15.0

> To unsubscribe, send a message to [log in to unmask] with following text in

> the BODY (NOT the subject field): SIGNOFF Technet

> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)

> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest

> Search the archives of previous posts at: http://listserv.ipc.org/archives

> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

> -----------------------------------------------------

> 



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------


ATOM RSS1 RSS2