>Does anyone have any direct experience uploading Lavenir FixLT Test
>Programs to a Trace 924
>Bare Board Tester (with a DEC PDP 11)?
>
>
>
Hi Fred,
You may have to hack (alter) some of the Lavenir header info in DEC EDT>
This is from another life, when I did such stuff. I don't have access to
such info, but would remember if I saw the file header again.
---OR---
Are you just trying to get it into the machine.
We read the lavenir file into a PC, then transfered it via modem into the
PDP-11/04. Then it must be named AUTO.ARL, and placing them into the
correct directory.
Finally, a background program sees the file, converts it, and loads it into
the trace tester directory.
Now you can "see" it from the Trace computer, and select the file.
This is such an elegant solution, one must wonder why Trace is not
supported any more. (Sarcasm)
====================================================================
George Franck
PWB Product Assurance Phone (703) 560-5000 x2648
E-Systems M/S N408 Fax (703) 280-4613
7700 Arlington Blvd E-Mail: [log in to unmask]
Falls Church Va 22046 E-Mail: [log in to unmask]
====================================================================
|
|
|