Guys,
We are designing a board with 40 mil BGA (1mm) on it. I am planning to have
bottom side non-vias plugged to prevent flux going into the vias during wave
while at the same time topside vias open. Fab house do not prefer plugging
from the both ends. Board has Ni-Ag surface finish.
How practical it is on 40 mil BGA as I do not see any problem on 50 mil
pitch BGA? Has any one done this way? I reason I do not want to mask from
the topside from cleaning point of view. Any comments.
re,
Ken Patel
______________________________________________________
Ken Patel Phone: (408) 490-6804
1708 McCarthy Blvd. Fax: (408) 490-6859
Milpitas, CA 95035 Beeper: (888) 769-1808
################################################################