You might try Total Organic Carbon.  We use it to monitor our copper baths and 
have found a 2000 PPM upper limit is satisfactory.  

                                Regards,

                                Jim Reed, Texas Instruments, Austin, TX

Voice = 512 250-7172,  
Fax =   512 250-7967,  
Email = [log in to unmask]
-------------
Original Text
>From cmaffe@[log in to unmask], on 7/29/96 9:06 AM:
To: technet@[log in to unmask]
Cc: jcarey@[log in to unmask], mbyrne@[log in to unmask], 
aarmitag@[log in to unmask]

     With higher tech product these days and the associated high aspect
     ratio copper plating chemistries, we're looking for a good method to
     determine when to carbon treat as a preventative measure.  For years
     I've used a guideline of carbon treating copper baths every 6 mos. or,
     if through put per gal was very high, perhaps quarterly.

     T&E results are so susceptible to sample prep, and I've never really
     found them to correlate to anything but perhaps extreme organic
     contamination.  I've never felt comfortable relying on those to
     indicate when to treat.

     Multiple thermal shock is another method I'm hearing is an indicator.
     We currently pass six or more, yet just went through a bath decant to
     minimize detrimental organic build up while awaiting installation of a
     new carbon treatment system.  The baths are only about 6 mos. old but
     with only about 3 months of production throughput.

     Appreciate any ideas or schemes that work for others, especially high
     volume, high tech.

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************



ATOM RSS1 RSS2