                                Hi Phil!

                                The BGA in question is a small one, only 100-balls, and a plastic part with no heat-sink.
                                It's on the bottomside of the board, and has to go through reflow one more time when the
                                topside is built.

                                As I said, everything looks fine at x-ray...it is inspected pretty closely too.

                                Our customer is the one who is worried about x-ray, not us. They can't get the device to
                                accept a program on some boards, and they are thinking that possibly x-ray damaged
                                the device.

                                Kind regards,

                                -Steve Gregory-
                                Senior Process Engineer
                                LaBarge Incorporated
                                Tulsa, Oklahoma
                                (918) 459-2285
                                (918) 459-2350 FAX





        Phillip Bavaro <[log in to unmask]>
                        Sent by: TechNet <[log in to unmask]>
                        09/27/2005 01:16 PM
                        Please respond to TechNet E-Mail Forum <[log in to unmask]>; Please respond to Phillip Bavaro <[log in to unmask]>
                                	
        To:     [log in to unmask]@SMTP@Exchange
        cc:     (bcc: Stephen R Gregory/LABARGE)
        Subject:        Re: [TN] X-ray inspection, can it damage devices?	


                                Hi Steve,

                                I haven't ever heard of or experienced any issues with an xray inspection system causing damage to a chip.    It is hard to believe that xrays momentarily exposed to a chip could cause damage.

                                I have seen some Altera BGAs that have difficulty getting good solder joint reflow due to the heatsinks on top of them, the pwb's 24 layers, and the sheer number of solderballs (1500+).  With your .050" copper core, I would look at the thermal reflow and make sure that all the balls on the BGAs have fully collapsed.

                                Was this BGA on the second side or first side reflowed?

                                It is tough sometimes to tell where the problem is if you don't have a board level test in place.

                                Phil


                                Steve Gregory <[log in to unmask]> wrote:
                                Good Mornin' Everyone!

                                I hope you all had a good weekend! I worked Saturday, but had
                                Sunday off. Sat around Sunday and watched the NASCAR race
                                at the "Monster Mile" in Dover Delaware. 20-year old Kyle Busch
                                gave Jimmie Johnson a run for his money finishing second at the
                                green/white/checkered ending....but I digress.....

                                Anyways, we built an assembly here that has a .050" copper core
                                in the center of it...not the same assembly as the one I did my "okie
                                cross-section" on).

                                It is double-sided SMT, and has BGA's on both sides. I'm doing x-ray
                                inspection with a Fein Focus Tiger 160, and in order to penetrate the
                                core and do a proper inspection of the solder joints and spheres of the
                                BGA's, the x-ray power is up around 120-130kv.

                                Our customer received a number of the assemblies from us (without test
                                from us, as they are prototypes and test hasn't been developed yet), and
                                they are having problems with one of the BGA's.

                                It's a 100-ball Max-7000 device from Altera, a CMOS EEPROM, and our
                                customer has been trying to program the device via on-board programming,
                                but some boards wont program. The x-ray inspection turned out fine. All
                                BGA's were inspected using oblique angles, so if there was an open joint,
                                it would have been seen.

                                They are worried that maybe the x-rays may have damaged the device.
                                Altera has told our customer that the x-rays shouldn't hurt the device.
                                I've got
                                a case number started via email in to Altera (since I can't talk to anyone
                                on
                                the phone), asking them myself if x-rays will damage the device. I'm also
                                going to call Fein Focus and talk to them as well.

                                But have any of you ever heard of x-ray damaging BGA's?

                                Kind regards,

                                -Steve Gregory-
                                Senior Process Engineer
                                LaBarge Incorporated
                                Tulsa, Oklahoma
                                (918) 459-2285
                                (918) 459-2350 FAX
                                __________________________________________________________________
                                This message may contain information that is privileged and confidential to
                                LaBarge, Inc. It is for use only by the individual or entity named above.
                                If you are not the intended recipient, you may not copy, use or deliver
                                this message to anyone. In such event, you should destroy the message and
                                kindly notify the sender by reply e-mail.

                                ---------------------------------------------------
                                Technet Mail List provided as a service by IPC using LISTSERV 1.8e
                                To unsubscribe, send a message to [log in to unmask] with following text in
                                the BODY (NOT the subject field): SIGNOFF Technet
                                To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
                                To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
                                Search the archives of previous posts at: http://listserv.ipc.org/archives
                                Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
                                -----------------------------------------------------

                                __________________________________________________
                                Do You Yahoo!?
                                Tired of spam?  Yahoo! Mail has the best spam protection around

                                ---------------------------------------------------
                                Technet Mail List provided as a service by IPC using LISTSERV 1.8e
                                To unsubscribe, send a message to [log in to unmask] with following text in
                                the BODY (NOT the subject field): SIGNOFF Technet
                                To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
                                To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
                                Search the archives of previous posts at: http://listserv.ipc.org/archives
                                Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
                                -----------------------------------------------------
                                http://mail.yahoo.com



                                __________________________________________________________________
                                This message may contain information that is privileged and confidential to LaBarge, Inc.  It is for use only by the individual or entity named above.  If you are not the intended recipient, you may not copy, use or deliver this message to anyone.  In such event, you should destroy the message and kindly notify the sender by reply e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2