We do button/selective plating all the time on flexible circuits for
impedance and other mechanical needs. Never seem to be a big deal even at
the 12drill/24pads

www.quickturnflex.com
Thank you, 
Jim Mahoney 
Quick Turn Flex Circuits, LLC 
Applications Project Manager 
P# 603-821-7071
M# 603-305-6250 
** This email and all attachments have been scanned prior to being sent** 
Confidentiality Notice: This page and any accompanying documents contain
information that is confidential, privileged or exempt from disclosure and
is intended for the exclusive use of the addressee. If you are not the
intended recipient, you are hereby notified that any disclosure, copying,
distribution or use of the contents of this information in any manner is
strictly prohibited.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Roger Stoops
Sent: Thursday, July 30, 2009 3:42 PM
To: [log in to unmask]
Subject: Re: [TN] Via plating question

And don't forget that 2 mils in vias translates to at least 2 mils on the
outer layers... Is it possible to double-up on vias if impedance is an
issue?

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Tony Steinke
Sent: Thursday, July 30, 2009 10:18 AM
To: [log in to unmask]
Subject: Re: [TN] Via plating question

It is difficult but it can be done. $$$$

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Upton, Shawn
Sent: Thursday, July 30, 2009 10:06 AM
To: [log in to unmask]
Subject: [TN] Via plating question

Quick question: I usually have via's plated to a minimum of 1mil.  I
have a high current design where I'd like to have those via's plated to
2mil (near 2oz, to match the 2oz spec for the layers) -- but the board
has some 15mil vias and is a 125mil thick board.  Would a typical board
house be ok with this?  I don't care about getting those 15mil mil
diameter via's to 2mil barrel plating, only the 32mil ones need to be
that thick.

Shawn Upton, KB1CKT
Test Engineer
Allegro MicroSystems, Inc
[log in to unmask]
603.626.2429/fax: 603.641.5336

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

Internal Virus Database is out-of-date.
Checked by AVG. 
Version: 7.5.560 / Virus Database: 270.12.36/2126 - Release Date: 5/21/2009
6:22 AM
 

Internal Virus Database is out-of-date.
Checked by AVG. 
Version: 7.5.560 / Virus Database: 270.12.36/2126 - Release Date: 5/21/2009
6:22 AM
 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2