In the case of A600, its main purpose is to illustrate by actual images (or illustrations), target, acceptable and rejectable conditions called out in the performance specs (601X series). So you have to use A600 as a companion to 6012, 6013, 6018, and not as a standalone acceptance document. The performance specs (601X) reference all test methods used during acceptance; some test methods are mentioned in A600, but more for reference.
José (Joey) Ríos, Sr QA Engineer
Mission Assurance Manager
Kavli Institute for Astrophysics & Space Research
Massachusetts Institute of Technology
[log in to unmask]<mailto:[log in to unmask]>
(617)324-6272
On Mar 5, 2018, at 1:36 PM, [log in to unmask]<mailto:[log in to unmask]> wrote:
Fellow TechNetters:
What is the purpose of IPC-A-600 (J) if this standard document is not stated/mentioned/referenced in the above TMs.
Is there a separate document for NEW Laminate Qualification.
Victor,
|
|
|