There is a spec JEDEC MO-269 that calls out requirements for DDR3 DIMMs.
Some of the datasheets from connector manufacturers give guidance for the mating boards. If you don't know the mfr part number for the actual connector you could try Molex 78316-0001. It is EOL, but maybe you can find a datasheet or one for the replacement part.
Both documents show chamfer dimensions and label them optional.
Best regards,
Raye Rivera
Raye Rivera | Quality Manager | Spirent Communications, Inc.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of TechNet automatic digest system
Sent: Thursday, February 22, 2018 10:00 PM
To: [log in to unmask]
Subject: TechNet Digest - 21 Feb 2018 to 22 Feb 2018 (#2018-33)
----------------------------------------------------------------------
Date: Thu, 22 Feb 2018 15:38:21 +0000
From: [log in to unmask]
Subject: DIMM Modules Gold Finger Edge - Bevel/Coined/Chamfer
Dell - Internal Use - Confidential
Fellow TechNetters:
Is there an consensus out there whether the gold finger edge on DDR3 DIMM Modules be beveled/Coined/Chamfer. I would appreciate any comments/remarks on this topic.
Victor,
-----Original Message-----
From: Hernandez, Victor G
Sent: Wednesday, February 21, 2018 1:10 PM
To: TechNet <[log in to unmask]>
Cc: Hernandez, Victor G <[log in to unmask]>
Subject: FW: [TN] DIMM Modules Gold Finger Edge - Bevel/Coined/Chamfer
Fellow TechNetters:
Any additional comments and/or concern over the gold finger edge being Beveled/Coined/Chamfered. Many a times do I see socket with gold plated wire contact gouges from DIMM product that has not been beveled/Coined/Chamfered, even bent pins.
Victor,
Spirent Communications e-mail confidentiality.
------------------------------------------------------------------------
This e-mail contains confidential and / or privileged information belonging to Spirent Communications plc, its affiliates and / or subsidiaries. If you are not the intended recipient, you are hereby notified that any disclosure, copying, distribution and / or the taking of any action based upon reliance on the contents of this transmission is strictly forbidden. If you have received this message in error please notify the sender by return e-mail and delete it from your system.
Spirent Communications plc
Northwood Park, Gatwick Road, Crawley, West Sussex, RH10 9XN, United Kingdom.
Tel No. +44 (0) 1293 767676
Fax No. +44 (0) 1293 767677
Registered in England Number 470893
Registered at Northwood Park, Gatwick Road, Crawley, West Sussex, RH10 9XN, United Kingdom.
Or if within the US,
Spirent Communications,
27349 Agoura Road, Calabasas, CA, 91301, USA.
Tel No. 1-818-676- 2300
|