Sorry I didn't indicate it but both the solder spheres and the soldering
alloy are eutectic Sn 63/ Pb 37.
The pin outs are shown below
Tom Gervascio
Principal Process Engineer
Sypris Electronics
Desk/VoiceMail 813-972-6763
Beeper 813-887-0098
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier /*
Sent: Tuesday, December 18, 2007 7:14 PM
To: [log in to unmask]
Subject: Re: [TN] BGA failures after OMPAC underfill
Hi Tom,
While you are not saying it, i am assuming your are using LF-SAC.
If so, than 214.5 C temperature under the center BGA joints is
insufficient for good soldering. By the way, time above liquidus (TAL)
of 84 sec is totally irrelvant for assuring good soldering; you need
about Liquidus+20C for 5 seconds at that solder ball.
Less squashed balls indicate that some balls (typically in the center)
did not melt and collapse. While I hate that SJ geometry [it gives you 2
stress concentration regions near the interfaces reducing reliability],
proper 'controlled collapse' is an indication of adequate wetting in the
whole array.
I have no idea where P16, J12, N7, M8 are located.
Pressing on fractured SJs externally is a temporary fix [you are making
electrical contact] which has been used for some Apple and Sony laptops
(see my column in Global SMT & Packaging magazine, October 2007).
Indeed, if in fact you have interfacial failures, Black Pad is one
possibility -however, you need to confirm this failure mode.
Werner
**************************************
See AOL's top rated recipes
(http://food.aol.com/top-rated-recipes?NCID=aoltop00030000000004)
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|