TECHNET Archives

March 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Kerry Bode <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Kerry Bode <[log in to unmask]>
Date:
Wed, 9 Mar 2005 06:59:56 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (53 lines)
Ofer.

Can you send photo as we maybe able to give you some advise/possible
solution.

Kerry

-----Original Message-----
From: Ofer Cohen [mailto:[log in to unmask]]
Sent: Wednesday, March 09, 2005 5:09 AM
To: [log in to unmask]
Subject: [TN] Shapes of pads

Hello, guys,
The problem - BGA with pitch of 1 mm and components in 0402 packages just
under the BGA.

The thickness of the PCB - 110 mils (2.7 mm), hence of through vias drilling
diameter is 12 mils (aspect ratio - 1:9). To keep annular ring of 5 mils the
pads diameter is 22 mils. To place components between two adjacent vias I
allowed 24 mils square pads over the via holes with deep hole plugging (50%
to 80% hole length). The plugging was pretty good (as seen in cross
sections) and the soldering results were also not too bad, although required
some touch up. This was acceptable for the production of low to medium
volume.

We are going now to manufacture in high volume. The solution is not
economical any more. Hence, I am considering three options, all of them
requires us to place pads for the components between the vias holes:
1.      Round 24 mils pads.
2.      Round 20 mils pads with tear drop to enhance the area
3.      19 mils square pads

Since the design will port in no time to LF soldering, but I can't test it
now due to lack of time and components - can you advise which is the best
solution?

Regards
Ofer Cohen
Manager
Quality Assurance, Reliability and Production Technologies
Seabridge Ltd. - A Siemens Company

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2