Hello,
I have a question on tenting of vias on PWB's. I have designed a 6
layer, military, mixed components (all on top side), LPI soldermask
board which will be run over the wave. I was planning on tenting vias
but did not specifically specify that on fab drawing. What we got back
is basically a board where all the vias are SMOBC. Does anyone have an
opinion on the board we recieved. Is tenting of vias really required?
Has the electrical integrity been compromised?
Any help/input will be greatly appreciated. Thanks,
-
Dave Hulbert , Sr. Circuit Designer | Voice: 978-927-8220
DATUM/Frequency & Time Systems, Inc. | Fax : 978-524-4891
34 Tozer Road | [log in to unmask]
Beverly, MA 01915 | http://www.ftsdatum.com
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
|
|
|