Hi Linda,

If you read further down the page it states:

"Component markings, reference designators and polarity indicators should be
mounted in such a manner that markings are visible. However, unless it is
otherwise required, it is an acceptable condition if these markings are
damaged during normal cleaning or processing."

So unless it states on the drawing that all reference designators MUST be
legible (the drawing overrides the -610), then I would say it would be just
a process indicator and not a defect.

Steve

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Linda Langley
Sent: Tuesday, September 28, 2010 9:27 AM
To: [log in to unmask]
Subject: [TN] Silkscreen

I have an assembly we had to replace a component, in the cleaning
process some of the silkscreen rubbed off. The assembly is ready to
ship!

 

IPC-610-D page 10-26, section 10.3.2 states Defect - Class 1,2,3 Missing
or illegible markings or reference designators for component location,
or component outlines.

 

Would this apply to bare board only?  Or do I have to replace
silkscreen?

 

 

Linda Langley CIT

Training Specialist

Jabil Circuit

248-292-6176


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2