Denny
Adding on to Phil's comments below. The 40% was in MIL-P-55110C in and
before 1980. Part of the results of IPC Multilayer Round Robin V
indicated that a lot of quality product was being rejected do things like
the teardrop voids, and resin recession. The "thermal-zone" concept was
proposed by George Smith, shortly after the round robin's release, and
the specifications changed to eliminate the resin recession evaluation
after stress. It was kept for quite some time in the prior to stress
microsection and as Phil said, due to a lack of industry problems with
the condition, was further removed as a rejectable requirement.
I'm sure more history is out there. I missed the meeting where they
plucked the magic 40% out of the air and plugged it into the spex in the
first place, so others will have to supplement if you need more.
Regards
Dave
__________________________________________________
David W. Bergman, V.P of Technical Programs
IPC
2215 Sanders Road
Northbrook, IL 60062-6135
847-509-9700 x340 Phone
847-509-9798 Fax
email [log in to unmask]
www http://www.ipc.org
faxback support 800-646-0089
---------------------------------------------------
On Wed, 18 Sep 1996 [log in to unmask] wrote:
> Dennis
>
> The statement about "Hole wall dielectric/plated hole separation" is a direct
> carry over from IPC-RB-276 Table 10 which as been in existence since 1992. It
> is the intent to allow hole-hole-wall-pullaway to any extent as long as the
> hole is not collapsed and the function is not degraded. This was a change
> from IPC-ML-950 which only allowed 40% hole-wall-pullaway. This is the first
> time any question has come up since RB-276 was issued and the suppliers and
> users seem satisfied.
>
> Phil Hinton
> [log in to unmask]
>
> ***************************************************************************
> * TechNet mail list is provided as a service by IPC using SmartList v3.05 *
> ***************************************************************************
> * To unsubscribe from this list at any time, send a message to: *
> * [log in to unmask] with <subject: unsubscribe> and no text. *
> ***************************************************************************
>
>
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
|
|
|