Hi Phil,

I dont think there's any standard to quantify the amount used.  usually
just slap it on and hope that all gaps are filled when you mechanically
fasten it down.
Have you considered using Thermal tapes/pads instead of grease?  Less messy
and easier to apply like double sided tapes.  Could be UV or heat
initiated.  More expensive though.

Regards,
Hann




Phil Nutting <[log in to unmask]> on 08/14/2001 10:42:09 AM

Please respond to "TechNet E-Mail Forum." <[log in to unmask]>; Please respond
      to Phil Nutting <[log in to unmask]>


To:   [log in to unmask]
cc:    (bcc: Hann Pang/US-Corporate/3M/US)
Subject:  [TN] Application of Thermal Grease



We use many TO-220 and TO-247 packages mounted to heatsinks.  Some of
these applications require the use of thermal grease.  The age old
question is how much grease is enough?  This is a political football
that is constantly tossed around.  Does anyone know of a manufacturer's
specification or some organization's standard that clearly defines how
much thermal grease is the correct amount?

Thanks,

Phil Nutting
Manufacturing Engineer
Kaiser Systems, Inc.

---------------------------------------------------------------------------------

Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2