We use quite a few solder sleeves for our harness assemblies. We have seen
no reliability failures in this type of solder joint. Though we do have
some problems with the installations, the percentage of these defects in
our total defects is insignificant. Based on our experience, they our an
acceptable solution.
Bruce Stilmack
GDLS-TO Manufacturing Engineer
(850) 574-4773
[log in to unmask]
"Bissonnette,
Jean-Francois"
<JBissonnette@WAB To
TEC.COM> [log in to unmask]
Sent by: TechNet cc
<[log in to unmask]>
Subject
[TN] Solder Sleeves
10/26/2005 12:30
PM
Please respond to
TechNet E-Mail
Forum
<[log in to unmask]>
; Please respond
to
JBissonnette@WABT
EC.COM
Hello Technetters,
I would like to have an expert's opinion on acceptability of solder
sleeves on harness assemblies. I have a few pictures of what I beleive
to be dubious solder flow. Help would really by appreciated.
Thanks in advance!
J-F
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
This is an e-mail from General Dynamics Land Systems. It is for the intended recipient only and may contain confidential and privileged information. No one else may read, print, store, copy, forward or act in reliance on it or its attachments. If you are not the intended recipient, please return this message to the sender and delete the message and any attachments from your computer. Your cooperation is appreciated.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|