Hi Hugh,
Any PWB with less than 0.8 mils of cu in the hole can be subject to via
barrel cracking [in fact, even thicker Cu plating can show barrel failures for
thicker PWBs and smaller hole diameters], drilling-, and plating-quality are also
important.
Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com
---------------------------------------------------