Bed of nails tester typically test utilizing DC signals.  Loaded PCB test
fixtures do use "Spring Pins" which require some frequency to travel
through.  The spring in the probe looks like an inductor to an AC signal. 
Reduce the inductance buy reducing the travel of the probe.  

Some test systems may utilize a spring probe at the connection of the
fixture to the tester also. 

Jeff Garland
Sales Engineer
Lavenir Technlogy, Inc.
603-431-6279
[log in to unmask]

----------
> From: Steve Tetorka <[log in to unmask]>
> To: [log in to unmask]
> Subject: "Pogo pins test probes"
> Date: Thursday, April 17, 1997 11:25 AM
> 
> 
> It appears that "pogo pins" used in "bed-of-nails" test fixtures may
cause 
> signal problems at 'high frequencies'.  This problem is due to the length
of 
> the probes.
> This same problem had occured with IC test sockets.  Your comments are 
> welcome.
> Thank you.
> 
>
***************************************************************************
> * TechNet mail list is provided as a service by IPC using SmartList v3.05
*
>
***************************************************************************
> * To subscribe/unsubscribe send a message <to: [log in to unmask]>  
*
> * with <subject: subscribe/unsubscribe> and no text in the body.         
*
>
***************************************************************************
> * If you are having a problem with the IPC TechNet forum please contact  
*
> * Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]     
*
>
***************************************************************************
> 

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************



ATOM RSS1 RSS2