Hi All,

Doug and Ioan both got my reply earlier, so may be the Technet is working
again. I'll try this post.

Just ran into an issue with an ESD Diode from Texas Instruments. PN#
is TPD1E10B06DPYR.

It is a tiny X1SON part that exhibits some pretty bad cracking after reflow:

https://photos.google.com/share/AF1QipPp6LspjK3p06cirTy8Z7pW6kUxN9-EdxKnrj7muxemJuPaTfoZJXq6QqWx9_eUXQ?key=aFV3OVh0WW5UbkNlSG0zTVM1ZjU3VjdIU2pYMDZB

The part is being placed with a MyData (MyCronic) MY19. There is no visible
cracking after pick and place and prior to reflow. The part package data in
the machine was verified against the datasheet dimensions and is correct.
The part is MSL-1. We have another X1SON part of another part number that
is not cracking. The label for these parts says the date code 2018, which
to me is very old.

The reflow profile was verified with a KICSTART-2 profiler and verified to
be well within FCT's AmpOne SAC305 parameters.

Roughly 2° per second ramp rate, in a RTS profile to a 239° max peak temp,
for a reflow time above 220° at 48 seconds. Pretty unremarkable profile.
Around 4-minutes long

You can only see these cracks AFTER reflow, they are not visible before
reflow. Have any of you ever seen anything like this?

TIA!

-- 
Steve Gregory
Kimco Design and Manufacturing
Process Engineer
(208) 322-0500 Ext. -3133
Cell Phone: (918) 706-2779

-- 


This email and any attachments are only 
for use by the intended 
recipient(s) and may contain legally privileged,
 confidential, proprietary 
or otherwise private information. Any 
unauthorized use, reproduction, 
dissemination, distribution or other 
disclosure of the contents of this 
e-mail or its attachments is strictly
 prohibited. If you have received 
this email in error, please notify the
 sender immediately and delete the 
original. 

ATOM RSS1 RSS2