TECHNET Archives

December 2010

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Werner Engelmaier <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Werner Engelmaier <[log in to unmask]>
Date:
Thu, 2 Dec 2010 15:01:04 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (590 lines)
Hi Leland,
That would point towards a weak interface or a Head-on-Pillow [ I sleep with my head 'on' not 'in' a pillow] situation.
Werner

 

 


 

 

-----Original Message-----
From: Leland Woodall <[log in to unmask]>
To: TechNet E-Mail Forum <[log in to unmask]>; Werner Engelmaier <[log in to unmask]>
Sent: Thu, Dec 2, 2010 2:53 pm
Subject: RE: [TN] BGA Failure Analysis Recommendations


Werner,



Actually the assembly failed a multi-cycle vibration test.  The test details 

were developed by a team of the customer's design and our R&D group.  The test 

itself is supposed to reflect a worst-case scenario of 10 years of product 

usage.



Leland



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier

Sent: Thursday, December 02, 2010 2:13 PM

To: [log in to unmask]

Subject: Re: [TN] BGA Failure Analysis Recommendations





 Hi Leland,

Most HALT tests are NOT accelerated reliability tests—the first tests for 

robustness and for the second you should follow IPC-9701.

Werner



 





 



 



-----Original Message-----

From: Leland Woodall <[log in to unmask]>

To: [log in to unmask]

Sent: Thu, Dec 2, 2010 11:01 am

Subject: Re: [TN] BGA Failure Analysis Recommendations





Richard,







We've priced but not yet purchased a BGA inspection scope.  I'll check



the one you've mentioned below from Practical.  It might be thousands



cheaper than what we're considering, and yet perform the same function.







As far as the component, it was not reworked.  The unit passed all our



in-house testing before being submitted to our HALT process.







The board finish is OSP.







Leland







-----Original Message-----



From: Stadem, Richard D. [mailto:[log in to unmask]] 



Sent: Thursday, December 02, 2010 10:57 AM



To: TechNet E-Mail Forum; Leland Woodall



Subject: RE: BGA Failure Analysis Recommendations







Or you have an internal via barrel crack. 



One way to tell is to purchase the small inspection prisms from



Practical Components. No BGA assembler/inspector should be without one.



You can use any standard microscope and the inspection mirror to see



under almost any BGA. The prism has a beveled edge so you can get right



down to the PWB, and you can angle the mirror to obtain the best view.



The prism is mounted on the end of a small wire that goes into a handle



much like an exacto knife handle. Imagine a 9-iron with a highly



polished face, but in miniature. To use it, you only need about .070"



clearance around the BGA periphery.







Back to the cause of the intermittent open. 



If the BGA was previously reworked, and this did not fix the issue, then



it is probably an internal via separation. These are quite often



mistaken for a bad BGA solder connection. If it is a solder joint issue,



it is usually either BP or BF.



What is the circuit board finish?







-----Original Message-----



From: TechNet [mailto:[log in to unmask]] On Behalf Of Leland Woodall



Sent: Thursday, December 02, 2010 9:36 AM



To: [log in to unmask]



Subject: [TN] BGA Failure Analysis Recommendations







Good morning, everyone!







I'm looking for some advice on how to best analyze a BGA problem.  We



had an assembly to fail in a reliability test, and have isolated the



problem to an intermittent contact on the BGA device.  When downward



pressure is applied to the component it will pass.  Without the



pressure, it won't.







That tells me we have either fractured a joint, had a ball to separate



from the package, or had a head in pillow (or non-wet) condition.







We don't have a BGA inspection scope in house, and I can only see two of



the four outside edges with the equipment I have.  Of course, nothing is



wrong with those.







We have both 2 and 3D xray machines, but neither detect a flawed



condition.







At this point, do I go with dye and pry, or conduct a series of cross



sections?







What's the recommendations of the pros out there that have dealt with



this?  Your suggestions are sincerely appreciated!







Leland Woodall







______________________________________________________________________



This email has been scanned by the MessageLabs Email Security System.



For more information please contact helpdesk at x2960 or



[log in to unmask] 



______________________________________________________________________







---------------------------------------------------



Technet Mail List provided as a service by IPC using LISTSERV 15.0



To unsubscribe, send a message to [log in to unmask] with following text



in



the BODY (NOT the subject field): SIGNOFF Technet



To temporarily halt or (re-start) delivery of Technet send e-mail to



[log in to unmask]: SET Technet NOMAIL or (MAIL)



To receive ONE mailing per day of all the posts: send e-mail to



[log in to unmask]: SET Technet Digest



Search the archives of previous posts at:



http://listserv.ipc.org/archives



Please visit IPC web site



http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional



information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100



ext.2815



-----------------------------------------------------







______________________________________________________________________



This email has been scanned by the MessageLabs Email Security System.



For more information please contact helpdesk at x2960 or [log in to unmask] 



______________________________________________________________________







---------------------------------------------------



Technet Mail List provided as a service by IPC using LISTSERV 15.0



To unsubscribe, send a message to [log in to unmask] with following text in



the BODY (NOT the subject field): SIGNOFF Technet



To temporarily halt or (re-start) delivery of Technet send e-mail to 



[log in to unmask]: SET Technet NOMAIL or (MAIL)



To receive ONE mailing per day of all the posts: send e-mail to 



[log in to unmask]: SET Technet Digest



Search the archives of previous posts at: http://listserv.ipc.org/archives



Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 



additional information, or contact Keach Sasamori at [log in to unmask] or 



847-615-7100 ext.2815



-----------------------------------------------------





 



______________________________________________________________________

This email has been scanned by the MessageLabs Email Security System.

For more information please contact helpdesk at x2960 or [log in to unmask] 

______________________________________________________________________



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to 

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to 

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 

additional information, or contact Keach Sasamori at [log in to unmask] or 

847-615-7100 ext.2815

-----------------------------------------------------


 

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2