Steve,

How much variation?  I was a under the impression that 106A  was self
limiting and that it was more of a manufacturing philosophy immersion vs.
conveyorized.  As a user of boards this is what I've always heard from the
manufacturer.  Evidently this might not be correct?  Could you elaborate?

Best Regards

Corey Peterson




"Stephen R. Gregory" <[log in to unmask]> on 02/26/99 06:10:06 PM

Please respond to "TechNet E-Mail Forum." <[log in to unmask]>; Please respond
      to [log in to unmask]

To:   [log in to unmask]
cc:    (bcc: Corey A Peterson/Mequon/RA/Rockwell)
Subject:  Re: [TN] Entek 106A OSP




In a message dated 2/26/99 12:21:53 PM Pacific Standard Time,
[log in to unmask] writes:

<< Debbie,

     There are several equipment manufacturers capable of building a
conveyorized OSP line. Adam Pill(Germany, represented in this country by
ECI),
Eidshun Engineering and FSL, to mention a few.

     With respect to the pros and cons of immersion versus conveyorized,
experience has shown that the uniformity of an OSP coating is improved by
 conveyorizing. Generally, the uniformity is a cosmetic thing, but
important
to some. If you have a high production load, conveyorized equipment should
 benefit from a productivity stand point.

      Regardless, OSP coatings are thin by nature, and obviously clear in
appearance.  In order to insure a cosmetically pleasing and robust
coating(necessary to prevent oxidation of the copper surface) equipment
design
is very important.

Best regards,

Michael Carano>>

Hi Debbie!

    Michael gave some good information, however, I'd like further amplify
the
importance of a uniform coating thickness, and one other reason a
conveyerized
process is better. In a water soluble environment where the use of fairly
active fluxes is the norm, variances in coating probably won't give you
much
heartburn (unless it's too thin and goes away on the first reflow), but in
the
no-clean world where flux activity is pretty lame, I've heard of people
having
problems getting good joints because the flux doesn't have enough "ooomph"
to
get through the OSP and also clean the metals surfaces.

    I've also had the experience from a non-conveyerized shop where they've
done the OSP coating first, then done the bed of nails test (which is bass-
ackwards) merely because of the logistics that it takes to move the panels
around...they kept things in the fab vendors panel size instead of the
production assembly panels because of the number of them (it's easier to
move
one big panel than it is to move a bunch of smaller ones), and the bed of
nails tester was set-up to do the larger panels. So I wound-up getting the
panels with a nice divot in the OSP coating...it was a good thing we built
those quickly because I don't think they would've done well sitting on the
shelves for any length of time with a hole in the coating like that...

-Steve Gregory-

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following
text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section
for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or
847-509-9700 ext.312
################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2