Greetings All!

Recently I was asked about IPC-A-600G pages 19 & 60.

Page 19 @ 2.3.3 states under Acceptable - Class 2, 3:
The blister or delamination does not span more than
25%
of the distance between adjacent conductive patterns.

Page 60 @ 3.1.4 states under Acceptable - Class 2, 3:
No evidence of delamination or blistering.

Page 19 deals with characteristics observable from the
surface.

Page 60 deals with visual observations made on
cross-sections only.

Before I reply I thought to see if you had any input.

With Respect,

Dave 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2