TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Michael Barmuta <[log in to unmask]>
Reply To:
Date:
Wed, 28 Feb 1996 09:21:35 PST
Content-Type:
TEXT/PLAIN
Parts/Attachments:
TEXT/PLAIN (66 lines)



On Tue, 27 Feb 1996 11:16:54 +600 CDT John Gully wrote:

> From: John Gully <[log in to unmask]>
> Date: Tue, 27 Feb 1996 11:16:54 +600 CDT
> Subject: SPEEDBOARD PLATING
> To: [log in to unmask]
> 
> Address,
> 
> It's been a few months, but I'm back on the NET Cowboys and 
> Cowgirls.  You previously knew me as John Gulley at Hitachi 
> Computer Products Division in Norman, OK.  I am know with 
> Compuroute Inc. in the BIG D of USA or Texas.
> 
> Enough of the intro.....
> 
> 
> Does anyone have experience in desmearing, etchbacking and
> eletroless plating SPEEDBOARD (PTFE-Teflon) materials.  We have 
> been using SPEEDBOARD for approximately a year and have had good 
> success through our processes.  Recently we have encountered some 
> process issues that are effecting overall quality.
> 
> Anyone's assistance on this matter is greatly appreciated.
> 
> Regards,
> 
> Thomas John Gulley
> Process Engineer 
> 
> p.s.
> 
> *In know way are we a competitor to PCB shops in the industry.
> We are a specialized company (ATE) that deals with 
> 
> 1.  exotic materials: C.E., Polyimide, Speedboard, Teflon, B.T.
> 2.  high layer counts:  16~24 layers
> 3.  SVH: .006~.014 PTHs
> 4.  metals: mainly gold boards, nickel, palladium
> 5.  We design, fab and assembly a majority of our products.
									
									
	John: Just an additional piece of information on the comments from 
Fred Paul and others.After holewall treatment with the sodium napthalene it 
is critical to use an organic solvent rinse(isopropyl alcohol)followed by a 
hot(140f)water rinse.If this is not done it may explain why voids were 
observed by one responder on sequential FR-4 boards processed thru els.cu 
after running teflon parts.BTW when we ran teflon it was run back to back 
with FR-4 and no voiding of els.was observed,we did increase the time for 
teflon by 30% in the els. cu bath.	Good luck			
									
									
					Regards				
					Michael Barmuta			
					Staff Engineer			
					Fluke corp.			
					Everett Wa.			
					(206)356-6076			
							