Reduce the pad size to 23, space/trace 5-6-5-6-5




At 03:32 PM 10/20/00 -0700, you wrote:
>I am looking for quick answers.
>
>We want to pass two traces of 6 mil wide traces between two plated holes.
>Hole pad size is 24 mil and holes are on 50 mil grid. 24 mil pad is based on
>12 mil drill size.
>
>This leave the following scenario :
>
>Hole /  4 mil airgap / 6 mil trace / 5 mil air gap / 6 mil trace / 5 mil
>airgap / Hole
>
>Questions:
>(1) Is 4 mil air gap OK for the fab house to work with? or
>(2) Should we reduce the drill size from 12 mil to 10 mils?
>
>Which one is better choice from cost and reliability point of view? We do
>not want to reduce the trace width for impedance needs.
>
>re,
>ken patel
>
>---------------------------------------------------------------------------
>------
>TechNet Mail List provided as a free service by IPC using LISTSERV 1.8d
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF TECHNET
>Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
>information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
>ext.5315
>---------------------------------------------------------------------------
>------

---------------------------------------------------------------------------------
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF TECHNET
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2