TECHNET Archives

July 2009

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Vladimir Igoshev <[log in to unmask]>
Reply To:
Date:
Sat, 4 Jul 2009 13:15:12 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (1 lines)
Hi Gaby,



I'd prefer to see SEM images, as optical are not as informative in this particular case. However, those "dark lines" do not look like cracks. The joints appear to have some Pb "concentrated" closer to the PCB interface implying that it could have been a mixed process.



If you don't have access to an SEM you can send them to me.



Regards,



Vladimir

SENTEC

------Original Message------

From: Gabriela

Sender: TechNet

To: [log in to unmask]

ReplyTo: TechNet E-Mail Forum

ReplyTo: Gabriela

Sent: Jul 4, 2009 03:54

Subject: [TN] Weird solder joints



Dear all,

By cross sectioning BGA solder joints on a failed assembly, I found that the

suspected joints are not uniform and that they contain unusual separation

areas.



I suspect mixed assembly and/or bad reflow profile.



Steve was so kind and enabled me to send the links.

Please may I have your opinion?

http://stevezeva.homestead.com/files/small.jpg



 



 <http://stevezeva.homestead.com/files/small1.jpg>

http://stevezeva.homestead.com/files/small1.jpg



 



 <http://stevezeva.homestead.com/files/small2.jpg>

http://stevezeva.homestead.com/files/small2.jpg



http://stevezeva.homestead.com/files/small3.jpg



 <http://stevezeva.homestead.com/files/small4.jpg>

http://stevezeva.homestead.com/files/small4.jpg



 





Gaby





---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------







SENTEC

11 Canadian Road, Unit 7.

Scarborough, ON M1R 5G1

Tel: (416) 899-1882

Fax: (905) 882-8812

www.sentec.ca


ATOM RSS1 RSS2