          I have just recieved results to a TMA test for z-axis expansion and
a TGA for weight loss on a 260 Tg polyimide material.  I was told that the
results are bad, however, I have nothing to bench mark the results against.
 Does anybody know what a typical good result for these tests are for this
type of material and or any other materials.  Any comments would be greatly
appreciated.

Thanks
Dennis

***************************************************************************