All - can anyone help me with what the following question. I don't have a copy of IPC-CC-830 and it'll take 2 weeks for me to get a copy.
What is acceptable minimum clearance of the masked off area's to the conformal coated area's?
The initial feedback I'm getting is 3.0mm, which seems quite large, as this is a smaller board (131mm x 32mm)
Coating being used is Lackwerke Peters, SL-1331-N-LF-D/23
I don't know if they will be spraying or painting the coating.
Michael Kuczynski
Siemens Healthcare Diagnostics Inc.
SHS DX LD ENG DES ELE ECS
Mgr. ECADS - Electrical 511 Benedict Ave.
914-524-3118 (Ph) Tarrytown, NY 10591
914-524-3322 (Fax) Mail Stop P25-1-C
[log in to unmask] <mailto:[log in to unmask]>